Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
1.
Int. arch. otorhinolaryngol. (Impr.) ; 26(4): 730-737, Oct.-Dec. 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1421643

ABSTRACT

Abstract Introduction Otosclerosis is characterized by the fixation of the stapes to the oval window, thereby impairing acoustic signal absorbance. A commonly used surgical technique for improving hearing in cases of otosclerosis is stapedotomy. However, it is unclear whether this surgery restores all the physical characteristics of the tympano-ossicular system. Objective To evaluate the tympano-ossicular system in individuals with fenestral otosclerosis pre and poststapedotomy using wideband tympanometry. Method A total of 47 individuals and 71 ears were assessed. The subjects were divided into three groups: presurgery otosclerosis; postsurgery; and a control group of normal-hearing adults. A handheld tympanometer with a wideband module (226-8,000 Hz) was used to take measurements at ambient pressure and under pressurized conditions. The level of statistical significance adopted was p ≤ 0.05. Results Acoustic absorbance at 226 Hz was low for all groups. At frequencies in the range 630 to 5,040 Hz, each group had a characteristic absorbance curve, allowing them to be distinguished from one another. In the presurgery group, absorbance values were below normal levels, with energy absorbance below 10%. Low energy absorbance was most evident at 1,000 Hz in the presurgery group, but this was not observed in the postsurgery group. Although there was an improvement in hearing, the surgery failed to restore the tympano-ossicular system to normal. Conclusion Wideband acoustic absorbance proved able to differentiate normal ears and otosclerotic ears pre and postsurgery, under both ambient pressure and pressurized conditions.

2.
Braz. j. otorhinolaryngol. (Impr.) ; 88(2): 194-203, Mar.-Apr. 2022. tab, graf
Article in English | LILACS | ID: biblio-1374721

ABSTRACT

Abstract Introduction: Endolymphatic hydrops is the pathophysiological substrate of Ménière's disease. The changes in the inner ear, transmitted to the middle ear through changes in the ossicular chain mobility, can be quantified by wideband tympanometry, through the measurement of the acoustic absorbance at multiple frequencies, represented by the sound energy absorbed by the middle ear, even at its early stages. Studying the behavior of the middle ear through the absorbance in patients with endolymphatic hydrops under ambient pressure and under peak pressure can be useful for detecting Ménière's disease. Objective: To characterize acoustic absorbance behavior in subjects with symptomatic and asymptomatic Ménière's disease compared to controls, in order to verify the ability of wideband tympanometry to detect Ménière's disease. Methods: We carried out a cross-sectional study with a diagnostic approach comparing the findings of wideband tympanometry at ambient pressure and peak pressure between the ears of the control group (n = 30), the asymptomatic group (n = 21) and the symptomatic group (n = 9). Results: Different peak pressure values were found between the ears of the control group (0daPa), the asymptomatic group (−11 daPa) and the symptomatic group (−192 daPa), with p < 0.05 by the Kruskal-Wallis test, Mann Whitney test and Bonferroni correction. Different absorbance values were found between the ears of the symptomatic group and the asymptomatic group compared to the control group for low frequencies at ambient pressure and peak pressure, with p < 0.05 by the Kruskal-Wallis test, Mann Whitney test and Bonferroni correction. Conclusions: The Wideband Tympanometry test was capable of identifying the presence of Ménières disease, and to differentiate between asymptomatic and symptomatic patients, when comparing them with healthy individuals.


Resumo Introdução: A hidropsia endolinfática é o substrato fisiopatológico da doença de Ménière. As alterações desencadeadas na orelha interna, transmitidas à orelha média pelas modificações na mobilidade da cadeia ossicular, podem ser quantificadas pela timpanometria de banda larga, através da medida da absorvância acústica sob múltiplas frequências, representadas pela energia sonora absorvida pela orelha média, mesmo em estágios iniciais de sua instalação. Estudar o comportamento da orelha média através da absorvância em pacientes com hidropisia endolinfática sob pressão ambiente e sob o pico de pressão pode ser útil na detecção da doença de Ménière. Objetivo: Caracterizar o comportamento da absorvância em indivíduos com diagnóstico da doença de Ménière sintomáticos e assintomáticos, comparados com controles, a fim de verificar a capacidade da timpanometria de banda larga em detectar variações clínicas relacionadas a possível hidropisia endolinfática. Método: Foi realizado um estudo transversal, com enfoque diagnóstico, que comparou os achados da timpanometria de banda larga na pressão ambiente e no pico de pressão entre orelhas do grupo controle (n = 30), grupo assintomático (n = 21) e grupo sintomático (n = 9). Resultados: Foram encontrados valores do pico de pressão diferentes entre orelhas do grupo controle (0 daPa), do grupo assintomático (-11 daPa) e do grupo sintomático (-192 daPa), com p <0,05 pelos testes de Kruskal-Wallis, Mann Whitney e correção de Bonferroni. Foram encontrados valores de absorvância diferentes entre orelhas do grupo sintomático e do grupo assintomático em relação ao grupo controle para as frequências baixas na pressão ambiente e na pressão de pico, com p < 0,05 pelos testes de Kruskal-Wallis, Mann Whitney e correção de Bonferroni. Conclusão: A timpanometria de banda larga foi um teste capaz de identificar a presença da doença de Ménière e de diferenciar os pacientes assintomáticos e sintomáticos, comparando-os com indivíduos hígidos.


Subject(s)
Humans , Endolymphatic Hydrops , Ear, Inner , Meniere Disease/diagnosis , Acoustic Impedance Tests , Cross-Sectional Studies
3.
Braz. j. otorhinolaryngol. (Impr.) ; 87(3): 290-297, May-Jun. 2021. tab, graf
Article in English | LILACS | ID: biblio-1285691

ABSTRACT

Abstract Introduction The cortical auditory evoked potential allows the possibility of objectively evaluating the entire auditory system, which is desirable in the pediatric population. Bone conduction auditory stimulation is recommended in the differential diagnosis of conductive hearing loss. However, there are not many studies of cortical auditory evoked potential using bone conduction. Objective The aim of this study was to characterize the response of cortical auditory evoked potential through bone conduction in normal-hearing neonates using an automated response analysis equipment. Methods This study included 30 normal-hearing neonates, without risk factors for hearing loss. The equipment used was the HEARlab automated response analysis and the cortical responses were evaluated at the frequencies of 500-4000 Hz through bone conduction, at intensity ranging from 0 to 60 dBnHL. The latencies and amplitudes were manually marked by experienced judges. Results Cortical auditory evoked potential responses were detected in 100% of the evaluated subjects and there was no difference regarding the cortical response of the neonates in relation to the variables of gender, ear and masking use. At an intensity of 60 dBnHL for the frequencies of 500, 1000, 2000 and 4000 Hz the latencies were 234; 241; 239 and 253 ms and the amplitudes were 15.6; 8.4; 6.2; 6.3 µV. The mean thresholds were 23.6; 28; 31 and 33.1 dBnHL, respectively. Conclusion It was possible to measure the cortical auditory evoked potential response in the neonatal population using bone vibrator as sound transducer and to draw the profile of the cortical auditory evoked potential latencies and amplitudes by frequencies at the intensity of 60 dBnHL and at the threshold.


Resumo Introdução O potencial evocado auditivo cortical traz a possibilidade de avaliar de forma objetiva todo o sistema auditivo, o que é desejável na população infantil. A estimulação auditiva por condução óssea é recomendada no diagnóstico diferencial da perda auditiva condutiva. Entretanto, não há muitos estudos de potencial evocado auditivo cortical com o uso do vibrador ósseo. Objetivo Caracterizar a resposta do potencial evocado auditivo cortical por vibrador ósseo em neonatos normo-ouvintes com equipamento de análise automática de resposta. Metodologia A pesquisa incluiu 30 neonatos normo-ouvintes e sem fator de risco para deficiência auditiva. Foi usado o equipamento de análise automática de resposta HEARlab e foram avaliadas as repostas corticais na frequências de 500 a 4000 Hz por vibrador ósseo, na intensidade de 0 a 60 dBnNA. As latências e amplitudes foram marcadas manualmente por juízes experientes. Resultados Foram detectadas respostas de potencial evocado auditivo cortical em 100% dos sujeitos avaliados. Não houve diferença na resposta cortical dos neonatos para as variáveis: sexo, orelha e uso do mascaramento. Para as frequências de 500, 1000, 2000 e 4000 Hz foram observadas as latências de 234; 241; 239 e 253 ms, as amplitudes de 15,6; 8,4; 6,2; 6,3 µV, na intensidade de 60 dBnNA, e os limiares médios de 23,6; 28; 31 e 33,1 dBnNA, respectivamente. Conclusão Foi possível obter a resposta do potencial evocado auditivo cortical na população neonatal com vibrador ósseo como transdutor de som e traçar o perfil das latências e amplitudes dos potencial evocado auditivo cortical por frequência nas intensidades de 60 dBnNA e no limiar.


Subject(s)
Humans , Infant, Newborn , Child , Bone Conduction , Evoked Potentials, Auditory , Auditory Threshold , Acoustic Stimulation , Evoked Potentials, Auditory, Brain Stem , Hearing
4.
Braz. j. otorhinolaryngol. (Impr.) ; 87(2): 193-199, mar.-abr. 2021. tab, graf
Article in Portuguese | LILACS | ID: biblio-1249357

ABSTRACT

Resumo Introdução: As substâncias tóxicas presentes na fumaça do cigarro podem danificar as células ciliadas da cóclea. Esse efeito foi investigado pela mensuração das emissões otoacústicas. Objetivo: Investigar o impacto de estímulos nas emissões otoacústicas, comparar neonatos com e sem exposição à fumaça de cigarro durante a gestação. Método: Testes de emissões otoacústicas evocadas transientes, evocadas por estímulo tipo clique e emissões otoacústicas por produto de distorção, evocadas por dois tons, foram feitos em ambas as orelhas, com um aparelho Interacoustic TITAN. O estudo incluiu 105 neonatos divididos em dois grupos: um grupo de estudo, que compreendeu 47 neonatos expostos à fumaça durante a gravidez; e um grupo controle constituído por 58 neonatos que não foram expostos. Todos os participantes apresentaram triagem auditiva neonatal normal. Resultados: Não foram encontradas diferenças estatísticas nos níveis de resposta das emissões otoacústicas por produto de distorção entre os grupos. Nos testes de emissões otoacústicas evocadas transientes, foram observados menores níveis de resposta no grupo de estudo do que no grupo controle na análise de bandas de frequências da orelha direita, com diferenças estatisticamente significantes nos sinais e relação sinal-ruído (exceto a 1 kHz). Conclusão: O impacto da exposição ao fumo pôde ser analisado por meio das emissões otoacústicas evocadas transientes em neonatos. O efeito da exposição à fumaça durante a gravidez foi evidenciado por uma redução nos níveis das emissões otoacústicas evocadas transientes no grupo exposto. Esse mesmo efeito não foi observado para as análises feitas nos níveis das emissões otoacústicas por produto de distorção.


Subject(s)
Female , Humans , Infant, Newborn , Pregnancy , Smoke , Otoacoustic Emissions, Spontaneous , Neonatal Screening , Hearing Tests , Noise
5.
Clinics ; 76: e2944, 2021. tab, graf
Article in English | LILACS | ID: biblio-1345817

ABSTRACT

OBJECTIVES: To analyze central auditory maturation in term and preterm infants during the first 3 months of life by comparing the latency and amplitude of cortical auditory-evoked potential at different frequencies. METHODS: In this study, 17 term and 18 preterm infants were examined; all had tested positive on the neonatal hearing screening test. Cortical auditory potential was investigated during the first and third months of life. The response of the cortical auditory-evoked potential was investigated at frequencies of 500, 1000, 2000, and 4000 Hz. The latency and amplitude of the cortical response were automatically detected and manually analyzed by three researchers with experience in electrophysiology. The results were compared using analysis of variance and the Bonferroni test. A significance level of 5% was used for all analyses. RESULTS: Latency values of cortical auditory-evoked potential in the first month of birth were significantly higher than those in the third month, and latency values of the preterm group were higher than those of the term group, regardless of the frequency and time of evaluation. In general, the latency of the cortical auditory-evoked potential was higher at high frequencies. Amplitude values in the third month of life were significantly higher than those in the first month for term and preterm infants. CONCLUSION: Central auditory maturation was observed in both groups but with different results between those born at term and preterm, with latencies of cortical auditory-evoked potential higher for the preterm group and at high frequencies.


Subject(s)
Humans , Infant, Newborn , Infant , Infant, Premature , Evoked Potentials, Auditory, Brain Stem , Biomarkers , Neonatal Screening , Evoked Potentials, Auditory
6.
Braz. j. otorhinolaryngol. (Impr.) ; 86(6): 687-695, Nov.-Dec. 2020. tab, graf
Article in English | LILACS | ID: biblio-1142606

ABSTRACT

Abstract Introduction: The study of the threshold level of cortical auditory response in adults has been investigated in previous studies. Due to maturational issues, little is known about these responses in neonates. Technological advances with automatic analysis devices now allow investigation in specific populations. Thus, new studies are needed to establish the feasibility of using this auditory potential to identify the lowest levels of responses in children. Objective: Verify and compare latency and amplitude in 80 dBnNA and the minimum level of cortical auditory response in term and preterm neonates. Methods: A cross-sectional, comparative study involving 59 neonates, 35 full-term births and 24 preterm births, with positive results in the Neonatal Hearing Screening. The Hearlab system was used to investigate the P1i auditory potential with tone burst stimulus at frequencies of 500, 1000, 2000 and 4000 Hz. The minimum response level search ranged from 80 to 0 dBNA and was detected automatically. The results were compared between groups, evaluating the latency and amplitude in 80 dBNA and the minimum level of cortical auditory response. Results: The mean values obtained for the minimum level of cortical auditory response in term group were 26 ± 8.81; 26.14 ± 6.97; 29 ± 7.65 and 29.43 ± 7.04 dBNA and for preterm neonates of 31.96 ± 10.41; 34.13 ± 11.34; 33.64 ± 11.03 and 37.73 ± 11.92 dBNA, for the frequencies of 500, 1000, 2000 and 4000 Hz, respectively. There was a difference between groups for the latency of P1i at 4000 Hz and the minimum response levels at 500, 1000 and 4000 Hz, with higher values for preterm infants. Conclusion: It was possible to obtain latency and amplitude values at 80 dBnNA and the minimum level of cortical response in term and preterm newborns, with different results between groups, with higher values in those born preterm.


Resumo Introdução: A investigação do nível mínimo de resposta auditiva cortical tem sido alvo de diferentes estudos em adultos. Devido a questões de maturação, pouco se sabe sobre essas respostas em recém-nascidos. Com o avanço tecnológico, dispositivos de análise automática surgiram com o objetivo de retomar essa avaliação em populações específicas. Assim, novos estudos são necessários para verificar a viabilidade do uso desse potencial auditivo na obtenção de níveis mínimos de respostas na criança. Objetivo: Verificar e comparar latência e amplitude em 80 dBnNA e o nível mínimo de resposta auditiva cortical em recém-nascidos a termo e pré-termo. Método: Estudo transversal, comparativo, envolvendo 59 neonatos, 35 nascidos a termo e 24 pré-termos, com resultados positivos na triagem auditiva neonatal. O sistema Hearlab foi utilizado para investigar o potencial auditivo P1i com estímulo tone burst nas frequências de 500, 1000, 2000 e 4000 Hz. A busca do nível mínimo de resposta variou de 80 a 0 dBNA e foi detectado automaticamente. Os resultados foram comparados entre os grupos, avaliando a latência e amplitude em 80 dBNA e o nível mínimo de resposta auditiva cortical. Resultados: Os valores médios obtidos para o nível mínimo de resposta auditiva cortical no grupo nascido a termo foram 26 ± 8,81; 26,14 ± 6,97; 29 ± 7,65 e 29,43 ± 7,04 dBNA e para recém-nascidos pré-termos foram de 31,96 ± 10,41; 34,13 ± 11,34; 33,64 ± 11,03 e 37,73 ± 11,92 dBNA, para as frequências de 500, 1000, 2000 e 4000 Hz, respectivamente. Houve diferenc¸a entre os grupos para a latência de P1i em 4000 Hz e os níveis mínimos de resposta em 500, 1000 e 4000 Hz, com valores maiores em Pré-termos. Conclusão: Foi possível obter valores de latência e amplitude em 80 dBnNA e o nível mínimo de resposta cortical em recém-nascidos a termo e Pré-termos, com resultados diferentes entre osgrupos, com valores maiores em pré-termos.


Subject(s)
Humans , Infant, Newborn , Infant, Premature , Evoked Potentials, Auditory , Acoustic Stimulation , Cross-Sectional Studies , Evoked Potentials, Auditory, Brain Stem , Hearing
7.
Braz. j. otorhinolaryngol. (Impr.) ; 85(2): 206-212, Mar.-Apr. 2019. tab, graf
Article in English | LILACS | ID: biblio-1001547

ABSTRACT

Abstract Introduction: The evaluation of cortical auditory evoked potential has been the focus of scientific studies in infants. Some authors have reported that automated response detection is effective in exploring these potentials in infants, but few have reported their efficacy in the search for thresholds. Objective: To analyze the latency, amplitude and thresholds of cortical auditory evoked potential using an automatic response detection device in a neonatal population. Methods: This is a cross-sectional, observational study. Cortical auditory evoked potentials were recorded in response to pure-tone stimuli of the frequencies 500, 1000, 2000 and 4000 Hz presented in an intensity range between 0 and 80 dB HL using a single channel recording. P1 was performed in an exclusively automated fashion, using Hotelling's T2 statistical test. The latency and amplitude were obtained manually by three examiners. The study comprised 39 neonates up to 28 days old of both sexes with presence of otoacoustic emissions and no risk factors for hearing loss. Results: With the protocol used, cortical auditory evoked potential responses were detected in all subjects at high intensity and thresholds. The mean thresholds were 24.8 ± 10.4 dB NA, 25 ± 9.0 dB NA, 28 ± 7.8 dB NA and 29.4 ± 6.6 dB HL for 500, 1000, 2000 and 4000 Hz, respectively. Conclusion: Reliable responses were obtained in the assessment of cortical auditory potentials in the neonates assessed with a device for automatic response detection.


Resumo Introdução: O potencial evocado auditivo cortical tem sido o foco de estudos científicos. Alguns autores observaram que a detecção automatizada de respostas é eficaz na exploração desses potenciais em lactentes, mas poucos relataram sua eficácia na busca de limiares. Objetivo: Analisar a latência, a amplitude e os limiares do potencial evocado auditivo cortical em recém-nascidos, com o uso de um dispositivo de detecção automática de resposta. Método: Estudo transversal, observacional. Os potenciais evocados auditivos corticais foram registrados em resposta a estímulos de tons puros nas frequências de 500, 1000, 2000 e 4000 Hz e apresentados em uma faixa de intensidade entre 0-80 dBNA, com o uso de gravação de canal único. O P1 foi feito de forma exclusivamente automática, com o uso do teste estatístico T2 de Hotelling. A latência e a amplitude foram obtidas manualmente por três examinadores. O estudo incluiu 39 recém-nascidos com até 28 dias de ambos os sexos, com presença de emissões otoacústicas e sem fatores de risco para perda auditiva. Resultados: Com o protocolo usado, as respostas dos PEAC foram detectadas em todos os indivíduos em alta intensidade e limiares. Os limiares médios foram 24,8 ± 10,4 dBNA, 25 ± 9,0 dBNA, 28 ± 7,8 dBNA e 29,4 ± 6,6 dBNA para 500, 1000, 2000 e 4000 Hz, respectivamente. Conclusão: Foram obtidas respostas confiáveis na avaliação dos potenciais auditivos corticais em recém-nascidos com um dispositivo para detecção de resposta automática.


Subject(s)
Humans , Male , Female , Auditory Cortex/physiology , Infant, Newborn/physiology , Evoked Potentials, Auditory/physiology , Reference Values , Auditory Threshold/physiology , Cross-Sectional Studies , Analysis of Variance , Otoacoustic Emissions, Spontaneous/physiology , Statistics, Nonparametric
8.
Braz. j. otorhinolaryngol. (Impr.) ; 85(2): 193-198, Mar.-Apr. 2019. graf
Article in English | LILACS | ID: biblio-1001557

ABSTRACT

Abstract Introduction: Tympanometry is currently the most frequently used tool for assessing the status of the middle ear, commonly assessed using a single 226 Hz tone. However, the use of the Acoustic Immittance Measures with a wideband stimulus is a promising high-resolution evaluation, especially in individuals known to have middle ear alterations, such as Down syndrome patients. Objective: The aim of this study was to analyze the acoustic absorbance measurements in children with Down syndrome. Methods: Cross-sectional study, approved by the institution's ethics committee. Data were collected from 30 children, with a mean age of 8.4 years, 15 with Down syndrome (DS-study group) and 15 children with typical development and no hearing complaints (control group). Energy absorbance was measured at frequencies of 226-8000 Hz at ambient pressure and at peak pressure as a function of frequency using TITAN equipment. Statistical analysis was performed using the established level of statistical significance of 5%. Results: With the 226 Hz probe tone, 30 ears of the control group and 22 of the study group exhibited Type A tympanograms, whereas Type B was observed in eight children in the study group. The mean acoustic absorbance ratio of the study group was lower than that of the control group at frequencies centered at 2520 Hz (p = 0.008) for those with normal tympanometry results, and 226-4000 Hz (p < 0.03) for those with a Type B tympanometry curve. Conclusion: The low energy absorption in the presence of normal tympanograms in children with Down syndrome may suggest middle ear abnormalities.


Resumo Introdução: A timpanometria é a ferramenta mais usada para avaliar o status da orelha média, comumente avaliada por meio de uma única frequência com o tom de 226 Hz. No entanto, o uso da medida de imitância acústica com estímulo de banda larga é uma avaliação de alta resolução promissora, especialmente em pacientes conhecidos por frequentemente apresentar alterações da orelha média, como na síndrome de Down. Objetivo: Analisar as medidas de absorvância acústica em crianças com síndrome de Down. Método: Estudo transversal, aprovado pelo comitê de ética da instituição. Foram coletados dados de 30 crianças, com idade média de 8,4 anos, sendo 15 com síndrome de Down (SD-grupo de estudo) e 15 crianças desenvolvimento típico e sem queixas auditivas (grupo controle). A absorvância de energia foi medida nas frequências de 226-8.000 Hz à pressão ambiente e no pico de pressão em função da frequência, usou-se o equipamento Titan. A análise estatística foi feita com o nível de significância estatística adotado de 5%. Resultados: Com o tom de sonda de 226 Hz foram observadas 30 orelhas do grupo controle e 22 do grupo estudo com timpanometria Tipo A e o Tipo B foi observado apenas em oito crianças do grupo estudo. A razão média de absorvância acústica do grupo estudo foi menor do que a do controle nas frequências centradas em 2.520 Hz (p = 0,008) para aqueles com resultados timpanométricos normais e de 226-4.000 Hz (p < 0,03) para aqueles com curva timpanométrica Tipo B. Conclusão: A baixa absorção de energia na presença de timpanogramas normais nas crianças com síndrome de Down pode sugerir anormalidades na orelha média.


Subject(s)
Humans , Male , Female , Child , Acoustic Impedance Tests/methods , Down Syndrome/physiopathology , Ear, Middle/physiopathology , Reference Values , Case-Control Studies , Cross-Sectional Studies , Statistics, Nonparametric , Ear Diseases/diagnosis , Ear Diseases/physiopathology
9.
Audiol., Commun. res ; 23: e1987, 2018. tab, graf
Article in Portuguese | LILACS | ID: biblio-983911

ABSTRACT

RESUMO Objetivo O objetivo desse estudo foi comparar a latência e amplitude do potencial evocado auditivo cortical P1i entre neonatos em estado de alerta e durante o sono leve. Métodos Vinte e cinco neonatos com emissões otoacústicas evocadas transientes presentes foram testados, por meio do potencial evocado auditivo cortical (PEAC), sendo dez em estado de alerta e 15 durante o sono leve. Para pesquisa dos potenciais corticais, utilizou-se o equipamento Hearlab System, de um canal, no módulo Cortical Tone Evaluation (CTE). O potencial P1i foi pesquisado de forma monoaural, na intensidade de 80 dBnNA, para as frequências de 500, 1000, 2000 e 4000Hz. A detecção do P1i foi feita de maneira automática pelo equipamento. A marcação da latência e amplitude foi realizada por três juízes. Resultados Não houve diferença estatisticamente significativa entre os dois grupos de neonatos para os valores de amplitude e latência, nas quatro frequências testadas. Conclusão Não houve influência do estado comportamental dos neonatos na avaliação do potencial cortical P1i.


ABSTRACT Purpose The aim of the present study was to compare latency and amplitude of the cortical auditory evoked response P1i among newborns in an alert state and during light sleep. Methods Twenty-five neonates with normal transient evoked otoacoustic emissions were tested with cortical auditory evoked potentials (CAEP): 10 were in an alert state and 15 in light sleep during testing. For the investigation of cortical potentials, a single-channel Hearlab System equipment, Cortical Tone Evaluation module (CTE), was used. The P1i potential was investigated monoaurally at an 80dBnHL intensity at 500, 1000, 2000 and 4000 Hz. P1i was automatically detected by the equipment. Latency and amplitude were marked by three judges. The responses of the newborn in an alert state were compared with those in light sleep. Results There was no statistically significant difference between the two groups of neonates for the amplitude and latency values at the four tested frequencies. Conclusion There was no influence of the neonates' behavioral state on the evaluation of the P1i auditory cortical potential.


Subject(s)
Humans , Infant, Newborn , Auditory Cortex , Sleep , Evoked Potentials, Auditory , Auditory Threshold , Cochlear Implants , Electroencephalography , Hearing Loss , Noise
10.
Braz. j. otorhinolaryngol. (Impr.) ; 83(2): 147-154, Mar.-Apr. 2017. tab, graf
Article in English | LILACS | ID: biblio-839421

ABSTRACT

Abstract Introduction: The use of hearing aids by individuals with hearing loss brings a better quality of life. Access to and benefit from these devices may be compromised in patients who present difficulties or limitations in traditional behavioral audiological evaluation, such as newborns and small children, individuals with auditory neuropathy spectrum, autism, and intellectual deficits, and in adults and the elderly with dementia. These populations (or individuals) are unable to undergo a behavioral assessment, and generate a growing demand for objective methods to assess hearing. Cortical auditory evoked potentials have been used for decades to estimate hearing thresholds. Current technological advances have lead to the development of equipment that allows their clinical use, with features that enable greater accuracy, sensitivity, and specificity, and the possibility of automated detection, analysis, and recording of cortical responses. Objective: To determine and correlate behavioral auditory thresholds with cortical auditory thresholds obtained from an automated response analysis technique. Methods: The study included 52 adults, divided into two groups: 21 adults with moderate to severe hearing loss (study group); and 31 adults with normal hearing (control group). An automated system of detection, analysis, and recording of cortical responses (HEARLab®) was used to record the behavioral and cortical thresholds. The subjects remained awake in an acoustically treated environment. Altogether, 150 tone bursts at 500, 1000, 2000, and 4000 Hz were presented through insert earphones in descending-ascending intensity. The lowest level at which the subject detected the sound stimulus was defined as the behavioral (hearing) threshold (BT). The lowest level at which a cortical response was observed was defined as the cortical electrophysiological threshold. These two responses were correlated using linear regression. Results: The cortical electrophysiological threshold was, on average, 7.8 dB higher than the behavioral for the group with hearing loss and, on average, 14.5 dB higher for the group without hearing loss for all studied frequencies. Conclusion: The cortical electrophysiological thresholds obtained with the use of an automated response detection system were highly correlated with behavioral thresholds in the group of individuals with hearing loss.


Resumo Introdução: O uso da amplificação sonora por pessoas com perda auditiva oferece uma melhor qualidade de vida. O acesso a esse recurso e o seu benefício podem ficar comprometidos no caso de pacientes que apresentem dificuldades ou limitações na avaliação audiológica tradicional comportamental, tais como neonatos e crianças pequenas, presença do espectro da neuropatia auditiva e do autismo, déficit intelectual e presença de estados demenciais de adultos e idosos. Essas populações (ou indivíduos) incapazes de participar de uma avaliação comportamental geram uma crescente demanda por métodos objetivos de avaliação auditiva. Os potenciais evocados auditivos corticais são usados há décadas, com a finalidade de estimar os limiares auditivos. Avanços tecnológicos atuais permitiram o desenvolvimento de equipamentos que possibilitam seu uso clínico, dotados de recursos que permitem maior precisão, sensibilidade e especificidade, além da possibilidade de detecção, análise e registro automatizados das respostas corticais. Objetivo: Determinar e correlacionar o limiar auditivo comportamental com o limiar auditivo cortical obtido em equipamento de análise automatizada das respostas. Método: Participaram do estudo 52 adultos, distribuídos em dois grupos: 21 com perda de grau moderado a severo (grupo estudo) e 31 com audição normal (grupo controle). Para o registro dos limiares comportamentais e corticais foi usado um equipamento dotado de um sistema com detecção, análise e registro automatizados das respostas corticais (HEARLab®). Os participantes permaneceram despertos, em um ambiente acusticamente tratado. Foram apresentados 150 estímulos tipo tone burst nas frequências de 500, 1.000, 2.000 e 4.000 Hz, por meio de fones de inserção em intensidades descendente-ascendente. O menor nível no qual o sujeito detectou a presença do estímulo sonoro foi definido como o limiar auditivo comportamental. O menor nível no qual uma resposta cortical estava presente foi definido como o limiar eletrofisiológico cortical. Essas duas respostas foram correlacionadas por meio da regressão linear. Resultados: O limiar eletrofisiológico cortical foi, em média, 7,8 dB superior ao comportamental para o grupo com perda auditiva e 14,5 dB superior, em média, para o grupo sem perda auditiva para todas as frequências estudadas. Conclusão: Os limiares eletrofisiológicos corticais obtidos por meio de um sistema de detecção automatizado de respostas estavam fortemente correlacionados com os limiares comportamentais no grupo de indivíduos com perda auditiva.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Auditory Threshold/physiology , Evoked Potentials, Auditory/physiology , Hearing Loss/physiopathology , Audiometry , Acoustic Stimulation , Signal Processing, Computer-Assisted , Case-Control Studies , Evoked Potentials, Auditory, Brain Stem/physiology
11.
Audiol., Commun. res ; 22: e1721, 2017. graf
Article in Portuguese | LILACS | ID: biblio-1038754

ABSTRACT

RESUMO Introdução O ruído é um dos principais problemas ambientais observados nos grandes centros urbanos. No caso do excesso de ruído presente na escola, pesquisas apontam que as principais fontes de ruído são os próprios membros da comunidade escolar, os quais, em geral, não percebem sua própria responsabilidade na geração do problema. Portanto, a fim de produzir um ambiente sonoro escolar saudável, é vital que sejam desenvolvidas ações educativas. Objetivo Apresentar um manual educativo para criação de hábitos e ambientes sonoros saudáveis, no contexto escolar. Métodos Foram consultadas bases de dados, bibliotecas virtuais, páginas eletrônicas, portais, livros, manuais e periódicos para a elaboração do manual, baseado nas teorias de educação em saúde. Resultados Apresentação do manual, descrevendo as seis etapas do programa educacional para a criação de hábitos e ambientes sonoros saudáveis. Conclusão A implantação desse manual educativo poderia contribuir com o empoderamento da comunidade escolar nas questões relacionadas ao ruído e favorecer a criação de hábitos e ambientes sonoros saudáveis.


ABSTRACT Introduction Noise is one of the main environmental problems observed in big cities. Studies on sound contamination in the school environment have shown that the main sources of noise pollution are the very members of the school community, although they generally fail to recognize their contribution to the problem. Hence, in order to create a healthy hearing environment in schools educational actions are vital. Purpose To present an educational manual for creating healthy hearing habits and environments in the school setting. Methods Databases, online libraries, sites, books, manuals and periodicals were consulted to devise the manual based on health education theories. Results The manual describing the six steps of the program for creating healthy hearing habits and environments was presented. Conclusion Implementation of this educational manual can contribute to school community empowerment regarding noise issues and favor the creation of healthy hearing habits and environments.


Subject(s)
School Health Services , Health Education , Noise Effects/adverse effects , Health Promotion , Noise/adverse effects
12.
Braz. j. otorhinolaryngol. (Impr.) ; 81(5): 491-497, Sept.-Oct. 2015. tab, graf
Article in English | LILACS | ID: lil-766294

ABSTRACT

ABSTRACT INTRODUCTION: Abnormalities in auditory function of newborns may occur not only because of preterm birth, but also from the use of medications and from diseases related to prematurity. OBJECTIVE: To analyze the inhibitory effect from stimulation of the olivocochlear efferent system on transient evoked otoacoustic emissions in preterm neonates, comparing these data with those from full-term neonates. METHODS: This was a prospective, cross-sectional, contemporary cohort study with 125 neonates, pooled into two groups: full-term (72 full-term neonates, 36 females and 36 males, born at 37-41 weeks of gestational age); and preterm (53 neonates, 28 males and 25 females, born at ≤36 weeks of gestational age, evaluated at the corrected gestational age of 37-41 weeks). Otoacoustic emissions were recorded using linear and nonlinear click-evoked stimuli, with and without contralateral stimulation. RESULTS: The inhibitory effect of the efferent pathway in otoacoustic emissions was different (p = 0.012) between groups, and a mean reduction of 1.48 dB SPL in full-term births and of 1.02 dB SPL in preterm births was observed for the non-linear click-evoked stimulus. CONCLUSION: The results suggest a reduced inhibitory effect of the olivocochlear efferent system on otoacoustic emissions in preterm neonates.


RESUMO Introdução: Alterações na função auditiva de recém-nascidos prematuros podem ocorrer não só devido ao nascimento antecipado, mas também pelo uso de medicamentos e por doenças relacionadas à prematuridade. Objetivo: Analisar o efeito inibitório da estimulação do sistema eferente olivo coclear sobre a amplitude das emissões otoacústicas evocadas transientes em recém-nascidos prematuros, comparando esses dados aos de recém-nascidos a termo. Método: Estudo prospectivo, de coorte contemporânea com corte transversal, com 125 recémnascidos, distribuídos em dois grupos: a termo (72 recém-nascidos a termo, 36 feminino e 36 masculino, nascidos entre 37-41 semanas de idade gestacional), e pretermo (53 recém-nascidos, 28 masculino e 25 feminino, nascidos com idade gestacional ≤ 36 semanas avaliados entre 37-41 semanas de idade gestacional corrigida). As emissões otoacústicas foram registradas a partir de estímulos clique lineares e não lineares, com e sem estimulação contralateral. Resultados: O efeito inibitório da via eferente nas otoemissões foi diferente (p = 0,012) entre os grupos, sendo observada uma redução média de 1,48 dB SPL nos nascimentos a termo e 1,02 dBSPL no grupo pretermo para o estímulo clique não-linear. Conclusão: Os resultados sugerem efeito inibitório do sistema eferente olivococlear reduzido sobre as emissões otoacústicas em recém-nascidos prematuros.


Subject(s)
Female , Humans , Infant, Newborn , Male , Efferent Pathways/physiopathology , Evoked Potentials, Auditory/physiology , Hearing Disorders/diagnosis , Otoacoustic Emissions, Spontaneous/physiology , Acoustic Stimulation , Cross-Sectional Studies , Hearing Disorders/physiopathology , Infant, Premature , Neonatal Screening , Prospective Studies , Risk Factors
13.
Rev. Assoc. Med. Bras. (1992) ; 60(6): 591-598, Nov-Dec/2014. tab
Article in English | LILACS | ID: lil-736311

ABSTRACT

Background: The recording of otoacoustic emissions (OAE) enabled us to prove that the cochlea is able not only to receive sounds but also to produce acoustic energy. Through the use of distortion-product otoacoustic emission measurements, the growth of the response was seen according to the intensity of the sound stimulus presented (growth curve). Objective: to determine the thresholds for the emergence of distortion-product otoacoustic emissions (DPOAE) on frequencies of 2000 and 4000 Hz with a stimulus varying from 20 to 65dB SPL, and to establish the slope values obtained in the growth curves. Methods: 39 neonates aged 5 to 28 days without risk indicators of hearing loss were studied. The DPOAE growth curves were obtained on the frequencies from 2000 Hz and 4000 Hz with a level of intensity ranging from 20 to 65dB SPL divided into two paradigms (20 to 40dB SPL and 40-65dB SPL). Results: there was a statistically significant difference in the thresholds for the emergence of DPOAE depending on the criteria used. The thresholds were on average higher at 4000 Hz than 2000 Hz and the slope was higher on average at 2000 Hz than 4000 Hz, although not statistically significant in either case. Conclusion: the thresholds were on average 30dB SPL at 2000Hz and 35dB SPL at 4000Hz. The slope values varied between 3 and 4 on average, reaching 15 in some cases. .


Introdução: o registro das emissões otoacústicas permitiu comprovar que a cóclea, além de receber os sons, produz energia acústica. Com a medida das emissões otoacústicas – produto de distorção (EOAPD), verifica-se o crescimento da resposta de acordo com a intensidade do estímulo sonoro apresentado (curva de crescimento). Objetivo: determinar os limiares de surgimento das EOAPD nas frequências de 2.000 e 4.000 Hz com estímulo de 20 a 65 dB NPS e estabelecer os valores de slope obtidos nas curvas de crescimento. Métodos: foram estudados 39 neonatos com 5 a 28 dias de vida sem indicadores de risco para perda auditiva. A captação das curvas de crescimento das EOAPD foi realizada em 2.000 e 4.000 Hz com nível de intensidade variando de 20 a 65 dB em dois paradigmas (20 a 40 dB NPS e 40 a 65 dB NPS). Resultados: houve diferença estatística significante dos limiares de surgimento das EOAPD dependendo do critério utilizado. Os limiares foram, em média, mais elevados em 4.000 Hz do que em 2.000 Hz, e o slope foi, em média, maior em 2.000 Hz do que em 4.000 Hz; porém, com diferença não significante em ambos os casos. Conclusão: os limiares de surgimento foram, em média, 30 dB NPS em 2.000 Hz e 35 dB NPS em 4.000 Hz. Os valores do slope variaram, em média, entre 3 e 4, chegando a 15 em alguns casos. .


Subject(s)
Female , Humans , Infant, Newborn , Male , Cochlea/physiology , Otoacoustic Emissions, Spontaneous/physiology , Acoustic Stimulation , Auditory Threshold/physiology , Cross-Sectional Studies , Hearing Tests , Neonatal Screening/methods , Prospective Studies , Reference Values , Term Birth/physiology
14.
CoDAS ; 26(5): 367-373, 2014. tab, graf
Article in English | LILACS | ID: lil-727060

ABSTRACT

Purpose: To analyze the presence of auditory cortical potential and its correlation with psychoacoustic detection of speech sounds as well as the latency of the P1, N1 e P2 components presented in free field in hearing impaired adults with and without amplification. Methods: We evaluated 22 adults with moderate to severe symmetrical bilateral sensorineural hearing loss, regular users of bilateral hearing aids. Speech sounds of low (/m/), medium (/g/) and high (/t/) frequencies were presented in sound field in decreasing intensities of 75, 65 and of 55 dBSPL in free field with and without hearing aids. The used equipment performs automatic statistical detection of the presence of response; forthermore, the latencies of waves P1, N1 e P2 were labeled and the psychoacoustic perception was registered. Results: The results demonstrated the increased presence of cortical response with hearing aids. We observed the correlation between psychoacoustic perception and automatic detection of 91% for the sounds /g/ and /t/ and ranged from 73 to 86% for the sound /m/. The averages of latencies P1-P2-N1 decreased with both increasing intensity and the use of hearing aids for the three sounds. The differences were significant for the sounds /g/ and /t/ in comparison with and without hearing aids. Conclusion: There was increase in the presence of cortical auditory evoked potential with hearing aids. Automatic detection of cortical response provided with hearing aids showed 91% agreement with the psychoacoustic perception of the speech signal. In the analysis of latency measures of the P1, N1 and P2 components, it was observed a decrease with the increase of the signal intensity and the use of amplification for the three speech stimuli /m/, /g/ and /t/.


Objetivo: Analisar a presença do potencial auditivo cortical e sua concordância com a detecção psicoacústica de sons de fala bem como a latência dos componentes P1, N1 e P2 apresentados em campo livre em adultos deficientes auditivos com e sem o uso da amplificação. Métodos: Foram avaliados 22 adultos com perda auditiva sensorioneural bilateral simétrica de grau moderado a severo, usuários regulares de prótese auditiva bilateral. Foram utilizados estímulos de fala de baixas (/m/), médias (/g/) e altas (/t/) frequências, apresentados em intensidades decrescentes de 75, 65 e 55 dBNPS em campo livre nas condições sem e com o uso de próteses auditivas. O equipamento utilizado realiza a detecção estatística automática da resposta; além disso, as latências das ondas P1, N1 e P2 foram marcadas e a percepção psicoacústica foi registrada. Resultados: Os resultados demonstraram o aumento da presença de resposta cortical na condição com prótese auditiva. Observou-se a concordância entre a percepção psicoacústica e a detecção automática de 91% para os sons /g/ e /t/ e variou de 73 a 86% para o som /m/. As médias das latências P1, N1 e P2 diminuíram tanto com o aumento da intensidade como com o uso da prótese auditiva para os três sons de fala. As diferenças foram significantes para os sons /g/ e /t/ na comparação sem e com prótese auditiva. Conclusão: Houve aumento da presença do potencial evocado auditivo cortical na condição com prótese auditiva. A detecção automática da presença de resposta cortical na condição com prótese auditiva apresentou 91% de concordância com a percepção psicoacústica do sinal de fala. Na análise das medidas de latência dos componentes P1, N1 e P2, observou-se a uma diminuição tanto com o aumento da intensidade do sinal como com o uso da amplificação para os três estímulos de fala /m/, /g/ e /t/.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Young Adult , Auditory Perception , Evoked Potentials, Auditory , Speech Perception , Auditory Threshold , Acoustic Stimulation/methods , Brazil , Hearing Aids , Hearing Loss, Sensorineural , Severity of Illness Index
15.
Audiol., Commun. res ; 19(1): 7-12, 03/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-705732

ABSTRACT

Objetivo : Verificar o desempenho de leitura e da habilidade auditiva de resolução temporal em crianças com dificuldades de leitura, após o treino auditivo. Métodos : Participaram deste estudo 20 crianças na faixa etária de 8 anos, sendo dez escolares com dificuldades de leitura (Grupo Estudo), e dez escolares sem dificuldades escolares (Grupo Controle). Todos os indivíduos foram submetidos à avaliação inicial e reavaliação da resolução temporal auditiva (Padrão de Frequência, Padrão de Duração e Gap in noise (GIN) e de leitura (Protocolo de Leitura Clínica e Teste de Consciência Fonológica - CONFIAS). O Grupo Estudo foi submetido a oito sessões de treinamento auditivo. Resultados : Verificou-se que o Grupo Controle obteve maior desempenho em todos os testes aplicados, quando comparado ao Grupo Estudo, na avaliação inicial e na reavaliação. A diferença do desempenho antes e depois do treinamento auditivo foi significativa para quase todas as tarefas no Grupo Estudo, exceto para a consciência fonológica. Conclusão : O treino auditivo foi efetivo para a melhora de desempenho nas habilidades auditivas temporais e de leitura em crianças que apresentam dificuldades de leitura. .


Purpose : To evaluate reading performance and auditory temporal resolution in children with reading difficulties after auditory training. Methods : Twenty 8 year- old children, 10 with reading difficulties (Study Group) and 10 without reading difficulties (Control Group) were assessed. All subjects participated in an initial assessment and reassessment of auditory temporal resolution (Frequency Pattern, Duration Pattern, and Gap in Noise (GIN) Tests) and reading performance (Clinical Reading Protocol and Phonological Awareness Test - CONFIAS). The Study Group was submitted to eight auditory training sessions. Results : The Control Group showed superior performance on all tests compared to the Study Group at both assessment and reassessment. The difference in performance before and after training was statistically significant for almost all tasks in the Study Group, except for phonological awareness. Conclusion : The auditory training proved effective for improving performance on auditory temporal and reading tasks in children with reading difficulties. .


Subject(s)
Humans , Male , Female , Child , Acoustic Stimulation/statistics & numerical data , Auditory Perception , Dyslexia , Reaction Time , Speech Perception , Early Diagnosis , Hearing Tests , Language Disorders , Learning Disabilities
16.
Rev. Soc. Bras. Fonoaudiol ; 15(2): 184-190, 2010. tab
Article in Portuguese | LILACS | ID: lil-553426

ABSTRACT

OBJETIVO: Analisar as Emissões Otoacústicas (EOA) em lactentes expostos à infecção intra-útero. MÉTODOS: Foi realizada a captação das EOA por transiente (EOAT) e das EOA produto de distorção (EOAPD) em 40 lactentes: 14 lactentes portadores e/ou expostos a algum tipo de infecção intra-útero (Grupo Estudo) e 26 lactentes sem intercorrências e sem indicadores de risco auditivo (Grupo Comparação). Os critérios de inclusão foram: Grupo Comparação: lactentes nascidos a termo, saudáveis e sem indicador de risco para alteração auditiva; Grupo Estudo: lactentes nascidos a termo, ou com idade gestacional corrigida entre 37 e 41 semanas na data de avaliação e portador ou exposto a algum tipo de infecção intra-útero. A análise estatística do conjunto de dados foi efetuada utilizando os testes estatísticos não paramétricos de Wilcoxon e Mann-Whitney, e a técnica de intervalo de confiança para média. RESULTADOS: Foram observados menores níveis de resposta e relação sinal/ruído das EOAT e EOAPD no Grupo Estudo em relação ao Grupo Comparação, com valores estaticamente significantes para as EOAPD em 8000 Hz e para EOAT em 1,5 Hz. CONCLUSÃO: A exposição à infecção intra-útero pode atenuar o nível de resposta das emissões otoacústicas no período neonatal.


PURPOSE: To analyze otoacoustic emissions (OAE) in infants exposed to intrauterine infection. METHODS: Transient OAE (TEOAE) and distortion product OAE (DPOAE) were performed in 40 infants: 14 with and/or exposed to some type of congenital infection (Study Group) and 26 without exposition and with no risk factors for hearing loss (Control Group). Inclusion criteria were: Control Group: healthy full-term infants, with no risk factors for hearing loss; Study Group: full-term infants or preterms with corrected gestational age between 37 and 41 weeks at the date of assessment, exposed to some type of intrauterine infection or with congenital infection. The statistical analysis of the data set was performed using the non-parametric tests of Wilcoxon and Mann-Whitney, and the technique of confidence interval for the mean. RESULTS: Lower levels of response and signal/noise ratio in TEOAE and DPOAE were observed in the Study Group, when compared to the Control Group, with significant statistical values for DPOAE in 8 kHz, and for TEOAE in 1.5 kHz. CONCLUSION: The exposure to intrauterine infections might attenuate the response level in OAE during the neonatal period.


Subject(s)
Humans , Infant , Fetal Diseases/etiology , Infections/congenital , Otoacoustic Emissions, Spontaneous
17.
Rev. Soc. Bras. Fonoaudiol ; 14(4): 521-527, 2009. tab
Article in Portuguese | LILACS | ID: lil-536479

ABSTRACT

OBJETIVO: Analisar as emissões otoacústicas (EOA) em lactentes submetidos a tratamento por medicação ototóxica no período neonatal. MÉTODOS: Foi realizada a captação das EOA por transiente (EOAT) e das EOA produto de distorção (EOAPD) em 40 lactentes: 14 lactentes submetidos a drogas ototóxicas por, no mínimo, cinco dias (grupo estudo) e 26 lactentes sem risco auditivo e sem intercorrências (grupo controle). A análise estatística do conjunto de dados foi efetuada utilizando-se os testes não-paramétricos de Wilcoxon e Mann-Whitney, e a técnica de intervalo de confiança para média. RESULTADOS: Foram observados menores níveis de resposta e relação sinal/ruído nas EOAPD para o grupo estudo, com valores estatisticamente significantes para as frequências de 3000, 6000 e 8000 Hz. CONCLUSÃO: A ação dos ototóxicos pode ser observada pela resposta típica das EOA em altas frequências, o que foi mais bem avaliado pelas EOAPD.


PURPOSE: To analyze the otoacoustic emissions (OAE) of infants exposed to ototoxic drugs during the neonatal period. METHODS: It was carried out the testing of transient OAE (TOAE) and distortion product OAE (DPOAE) with 40 infants: 14 infants exposed to ototoxic drugs for, at least, five days (study group), and 26 infants with no risks for hearing loss and no complications during the neonatal period (control group). The statistical analysis was performed using the non-parametric tests of Wilcoxon and Mann-Whitney, and the confidence interval for the average technique. RESULTS: Lower levels of response and signal/noise relation of DPOAE were observed in the study group, with statistically significant values for the frequencies of 3000, 6000 and 8000 Hz. CONCLUSION: The action of the ototoxic drugs can be observed by the typical response of OAE in high frequencies, which was better evaluated by the DPOAE.

18.
Pró-fono ; 18(1): 49-56, jan.-abr. 2006. tab, graf
Article in Portuguese | LILACS | ID: lil-427252

ABSTRACT

TEMA: tem sido sugerido que a função do sistema olivo coclear medial (SOCM) pode ser avaliada pelo efeito de supressão das emissões otoacústicas por transientes (EOAT). O ruído competitivo tem um efeito inibitório no funcionamento das células ciliadas externas reduzindo o nível das emissões otoacústicas. Apesar de não haver crescimento pós natal da cóclea, o crescimento da orelha média e o desenvolvimento do processamento auditivo continuam após o nascimento. OBJETIVO: analisar as mudanças no SOCM relacionadas à idade por meio da supressão das EOAT em lactentes saudáveis. MÉTODO: 25 lactentes a termo sem indicadores de risco auditivo foram avaliados em dois momentos: ao nascimento e no sexto mês de vida. Nas duas idades as EOAT foram captadas no modo "Quickscreen", estímulo clique não linear a 78dB peNPS, nas duas orelhas, com e sem ruído contralateral apresentado a 60dB NPS. RESULTADOS: a análise dos dados por meio da ANOVA revelou significante supressão contralateral das EOAT em ambos grupos, porém tanto os níveis das EOAT quanto a magnitude da supressão contralateral das EOAT foram menores no sexto mês de vida quando comparados com a fase neonatal (p<0,01). O efeito de supressão das EOAT no período neonatal foi 2,81dB (± 0,19dB) e no sexto mês de vida foi 1,41dB (± 0,29dB). CONCLUSAO: a magnitude da supressão das EOAT diminuiu do nascimento ao sexto mês de idade. A associação entre a estimulação acústica contralateral e um sistema, disponível comercialmente, rápido na medida das EOAT possibilita o monitoramento não invasivo dos mecanismos eferentes auditivos e parece ser clinicamente promissor na avaliação do estado coclear e do desenvolvimento da função eferente auditiva de lactentes de risco.


Subject(s)
Humans , Male , Female , Infant, Newborn , Infant , Audiometry/methods , Cochlea/physiology , Evoked Potentials, Auditory, Brain Stem/physiology , Hearing Loss, Noise-Induced/diagnosis , Otoacoustic Emissions, Spontaneous , Olivary Nucleus/physiology , Age Distribution , Analysis of Variance , Acoustic Stimulation/methods , Acoustic Stimulation/standards , Audiometry/standards , Sex Distribution
19.
Pró-fono ; 17(2): 133-140, maio-ago. 2005. tab
Article in Portuguese | LILACS | ID: lil-424177

ABSTRACT

TEMA: as emissões otoacústicas (EOA) são consideradas como o principal método dos programas de triagem auditiva neonatal (PTAN). OBJETIVO: analisar as EOA de neonatos avaliados em PTAN. MÉTODO: foi realizada captação das EOA por transiente em 1000 lactentes. Os dados foram analisados por modelo de análise de variância multivariada (Manova). RESULTADOS: foram calculadas tabelas de referência para os níveis das EOA geral e por banda de freqüência, segundo o gênero e a orelha. A duração do exame na maternidade foi menor do que no ambulatório. CONCLUSÃO: o nível das EOA foi influenciado pelo gênero e orelha, exceto para 0,7kHz, porém não foi observada diferença entre as respostas dos neonatos sem e com risco auditivo.


Subject(s)
Female , Humans , Infant, Newborn , Male , Hearing Loss/diagnosis , Neonatal Screening , Otoacoustic Emissions, Spontaneous/physiology , Brazil , Hearing Loss/etiology , Multivariate Analysis , Program Evaluation , Risk Factors , Sensitivity and Specificity , Sex Distribution , Sex Factors
20.
Pediatria (Säo Paulo) ; 27(2): 126-134, 2005. ilus, tab
Article in Portuguese | LILACS | ID: lil-412678

ABSTRACT

Objetivo: relatar um caso de grave perda auditiva neonatal assiaciada a hiperbilirrubinemia por deficiência de glicose-6 fosfato desidrogenase. Descrição: um recé-nascido a termo, adequado para a idade gestacional, realizou triagem auditiva neonatal por método de emissões otoacústicas / Objective: to report a case of serious neonatal loss associated to hypeerbilirubinemia in a newbornwith glucose-6-phosphate dehydrogenase deficiency...


Subject(s)
Humans , Infant, Newborn , Hearing Loss , Infant, Newborn , Jaundice, Neonatal/complications , Glycogen Storage Disease/etiology
SELECTION OF CITATIONS
SEARCH DETAIL